Related Experiment Video
Updated: Jul 29, 2025

In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
Pharmacokinetics and safety of candidate tocilizumab biosimilar CT-P47 versus reference tocilizumab: a randomized,
Kyung-Sang Yu1, Byungwook Kim1, Dongseong Shin2
1Department of Clinical Pharmacology and Therapeutics, Seoul National University College of Medicine and Hospital, Seoul, Republic of Korea.
Background:
CT-P47 is a candidate tocilizumab biosimilar. This study assessed the pharmacokinetic (PK) equivalence of CT-P47 and European Union-approved reference tocilizumab (EU-tocilizumab) in healthy Asian adults.
Research Design And Methods:
This double-blind, multicenter, parallel-group trial randomized healthy adults (1:1) to receive a single (162 mg/0.9 mL) subcutaneous dose of CT-P47 or EU-tocilizumab. The primary endpoint (Part 2) was PK equivalence by area under the concentration - time curve (AUC) from time zero to last quantifiable concentration (AUC0-last), AUC from time zero to infinity (AUC0-inf), and maximum serum concentration (Cmax). PK equivalence was concluded if 90% confidence intervals (CIs) for the ratios of geometric least-squares means (gLSMs) were within the 80-125% equivalence margin. Additional PK endpoints, immunogenicity, and safety were evaluated.
Results:
In Part 2, 289 participants were randomized (146 CT-P47; 143 EU-tocilizumab); 284 received study drug. AUC0-last, AUC0-inf, and Cmax were equivalent between CT-P47 and EU-tocilizumab: 90% CIs for the ratios of gLSMs were within the 80-125% equivalence margin. Secondary PK endpoints, immunogenicity, and safety were comparable between groups.
Conclusions:
CT-P47 demonstrated PK equivalence with EU-tocilizumab and was well tolerated, following a single dose in healthy adults.
Clinical Trial Registration:
www.clinicaltrials.gov identifier is NCT05188378.