Related Experiment Video
Updated: Jul 29, 2025

Confocal Imaging of Confined Quiescent and Flowing Colloid-polymer Mixtures
Published on: May 20, 2014
Transient Gel Electrophoresis of a Spherical Colloidal Particle
1Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan.
Abstract:
The general theory is developed for the time-dependent transient electrophoresis of a weakly charged spherical colloidal particle with an electrical double layer of arbitrary thickness in an uncharged or charged polymer gel medium. The Laplace transform of the transient electrophoretic mobility of the particle with respect to time is derived by considering the long-range hydrodynamic interaction between the particle and the polymer gel medium on the basis of the Brinkman-Debye-Bueche model. According to the obtained Laplace transform of the particle's transient electrophoretic mobility, the transient gel electrophoretic mobility approaches the steady gel electrophoretic mobility as time approaches infinity. The present theory of the transient gel electrophoresis also covers the transient free-solution electrophoresis as its limiting case. It is shown that the relaxation time for the transient gel electrophoretic mobility to reach its steady value is shorter than that of the transient free-solution electrophoretic mobility and becomes shorter as the Brinkman screening length decreases. Some limiting or approximate expressions are derived for the Laplace transform of the transient gel electrophoretic mobility.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Electrophoresis: Overview
There...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Colloids and Suspensions

