Improved demodulated phase signal resolution for carrier signals with small modulation index by clipping and
1Department of Applied Metrology, Institute of Electrical Information Technology, TU Clausthal, Clausthal-Zellerfeld, Germany. yu@iei.tu-clausthal.de.
Abstract:
Digitization of phase-modulated carrier signals with a commercially available analog-to-digital converter (ADC) is a common task in many communication and sensor applications. ADCs deliver phase-modulated digital carrier signals, which are numerically demodulated in order to extract the relevant information. However, the limited dynamic ranges of available ADCs limit the carrier-to-noise ratio of carrier signals after digitization. Correspondingly, the resolution of the demodulated digital signal is degraded. We demonstrate a sampling method with a simple demodulation scheme for phase-modulated signals with a small modulation index. Our new scheme overcomes the limitation due to digital noise defined by the ADC. Through simulations and experiments, we provide evidence that our method can improve the resolution of the demodulated digital signal significantly, when the carrier-to-noise ratio of phase-modulated signals is limited by digital noise. We employ our sampling and demodulation scheme to solve the problem of a possible degradation of measurement resolution after digital demodulation in heterodyne interferometers measuring small vibration amplitudes.
Related Concept Videos
Reconstruction of Signal using Interpolation
Upsampling
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Downsampling
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
NMR Spectrometers: Resolution and Error Correction
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...