Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Factors Associated with the Underestimation of Manual CPAP Titration Pressure
Po-Yueh Chen1,2, Nguyen-Kieu Viet-Nhi3, Yen-Chun Chen4,5
1Department of Otolaryngology, Wan Fang Hospital, Taipei Medical University, Taipei 110, Taiwan.
Abstract:
During the SARS-CoV-2 pandemic, the use of in-laboratory positive airway pressure (PAP) titration studies was not routinely suggested. PAP pressure prediction calculations are emerging as alternative methods for the treatment of these patients. The underestimation of PAP titration pressure usually leads to unsatisfactory results for PAP therapy. This study aimed to evaluate the factors associated with the underestimation of PAP titration pressure when using PAP pressure prediction equations. Estimated PAP pressure formulas based on body mass index (BMI) and apnea-hypopnea index (AHI) were chosen to validate the accuracy of equations in the successful prediction of titration pressure. Among 341 adult patients diagnosed with obstructive sleep apnea (OSA) by overnight polysomnography (PSG) and who received overnight PAP titration in order to select a successful pressure, the mean age of the total subjects was 55.4 years old and 78.9% of patients were male. The average BMI and AHI scores were 27.1 ± 4.8 and 37 ± 21.7, respectively. After multivariate stepwise regression analysis, the odds ratio of participants with a pretitration AHI was 1.017 (95% CI: 1.005-1.030). Only the severity of OSA was significantly different between the underestimated group and the adequately assessed group. In conclusion, a high AHI, but not BMI, is associated with an underestimated CPAP titration pressure in adult patients with OSA.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings