Related Experiment Video
Updated: Jul 29, 2025

Studying the Activity of Neuropeptides and Other Regulators of the Excretory System in the Adult Mosquito
Published on: August 24, 2021
In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using Different Sodium Hypochlorite
Sanda Ileana Cîmpean1, Radu Marcel Chisnoiu1, Adela Loredana Colceriu Burtea1
1Department of Odontology, Endodontics and Oral Pathology, "Iuliu Hațieganu" University of Medicine and Pharmacy, 33 Moților Street, 400001 Cluj-Napoca, Romania.
Abstract:
Background and Objectives: The aim of this study was to compare the accuracy of three types of electronic apex locators (EALs) when two different concentrations of NaOCl irrigation solutions are used by two operators. Materials and Methods: After creating the access cavities for 20 single rooted extracted teeth, the actual canal length (ACL) of each canal was determined visually using a #10 file and magnification. The teeth were subsequently inserted in plastic molds filled with alginate. The electronic measurement of root canal length (EWL) was performed using three different electronic apex locators: Root ZX II, Apex ID, and Dual Pex. Two independent operators, an endodontic specialist with 20 years practice and an undergraduate student in the final year of study, performed the irrigation procedures with two different concentrations of NaOCl (2% and 5.25%), and then measured the EWL using each of the EALs. The accuracy of all EALs, was determined in each case by subtracting the EWL from the ACL. Statistical analyses were performed using one-way ANOVA test. Results: In the presence of 2% NaOCl solution, for a margin error of ±0.5 mm, Root ZX II, Apex ID, and Dual Pex presented an accuracy of 90%, 80%, and 85% respectively. The increase in the concentration of the irrigation solution affected the accuracy of Root ZX II and Apex ID for both operators, diminishing it to 75% for the same margin error, but improved Dual Pex's accuracy to 100%. Conclusions: The best accuracy in working length determination was obtained by Root ZX II for 2% NaOCl solution and by Dual Pex for 5.25% NaOCl solution with no significant statistical difference when compared.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Determining the pH of Salt Solutions

