Related Experiment Video
Updated: Jul 29, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Effects of ephedrine and phenylephrine on cerebral oxygenation: observational prospective study using near-infrared
Yasunori Kubo1, Tomonori Kubo2, Takayuki Toki2
1Department of Anesthesiology and Critical Care Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, N15 W7, Kita-Ku, Sapporo, 0608638, Japan. hayatokirin@gmail.com.
Abstract:
It has been reported that cerebral oxygenation (ScO2) measured by near infrared spectroscopy is maintained or increased by treatment with ephedrine, whereas almost all previous reports demonstrated that phenylephrine reduced ScO2. As the mechanism of the latter, the interference of the extracranial blood flow, that is extracranial contamination, has been suspected. Accordingly, in this prospective observational study, we utilized time-resolved spectroscopy (TRS), in which the effect of extracranial contamination is thought to be minimal, and evaluated whether the same result was obtained. We measured the changes in ScO2 as well as the total cerebral hemoglobin concentration (tHb) after treatment with ephedrine or phenylephrine during laparoscopic surgery by using a tNIRS-1 (Hamamatsu Photonics, Hamamatsu, Japan), which is a commercial instrument utilizing TRS. Based on a mixed-effects model with random intercepts for ScO2 or tHb including mean blood pressure, the mean difference and 95% confidence interval were evaluated as well as the predicted mean difference and its confidence interval using the interquartile range of mean blood pressure. Fifty treatments with ephedrine or phenylephrine were done. The mean differences of ScO2 were less than 0.1% and the predicted mean differences were less than 1.1% for the two drugs. The mean differences of tHb were less than 0.02 μM and the predicted mean differences were less than 0.2 μM for the drugs. The changes in ScO2 and tHb after treatments with ephedrine and phenylephrine were very small and clinically insignificant when measured by TRS. Previous reports about phenylephrine may have been affected by extracranial contamination.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020