Related Experiment Video
Updated: Jul 29, 2025

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Securement of Umbilical Venous Catheter Using Cyanoacrylate Glue: A Randomized Controlled Trial
Vito D'Andrea1, Giorgia Prontera1, Giovanni Pinna2
1Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy.
Objective:
To evaluate the role of cyanoacrylate glue in reducing dislodgement of umbilical venous catheters (UVCs).
Study Design:
This was a single-center, randomized, controlled, nonblinded trial. All infants requiring an UVC according to our local policy were included in the study. Infants with a UVC with a centrally located tip as verified by real-time ultrasound examination were eligible for the study. Primary outcome was the safety and efficacy of securement by cyanoacrylate glue plus cord-anchored suture (SG group) vs securement by suture alone (S group), as measured by reduction in dislodgment of the external tract of the catheter. Secondary outcomes were tip migration, catheter-related bloodstream infection, and catheter-related thrombosis.
Results:
In the first 48 hours after UVC insertion, dislodgement was significantly higher in the S group than in the SG group (23.1% vs 1.5%; P < .001). The overall dislodgement rate was 24.6% in the S group vs 7.7% in the SG group (P = .016). No differences were found in catheter-related bloodstream infection and catheter-related thrombosis. The incidence of tip migration was similar in both groups (S group 12.2% vs SG group 11.7%).
Conclusions:
In our single-center study, cyanoacrylate glue was safe and effective for securement of UVCs, and particularly effective in decreasing early catheter dislodgments.
Trial Registration:
UMIN-CTR Clinical Trial; Registration number: R000045844.