Related Experiment Video
Updated: Jul 28, 2025

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
The HI-FIVE Trial: A Prospective Trial Using 4-Dimensional 68Ga Ventilation-Perfusion Positron Emission
Nicholas W Bucknell1, Nicholas Hardcastle2, Beverley Woon3
1Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia; Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia.
Purpose:
Functional lung avoidance (FLA) radiation therapy aims to spare regions of functional lung to reduce toxicity. We report the results of the first prospective trial of FLA using 4-dimensional gallium 68 ventilation-perfusion positron emission tomography-computed tomography (68Ga-4D-V/Q PET/CT).
Methods And Materials:
Inclusion criteria required a diagnosis of stage III non-small cell lung cancer and the ability to undergo radical-intent chemoradiation therapy. Functional volumes were generated using planning 68Ga-4D-V/Q PET/CT. These volumes were used to generate a clinical FLA plan to 60 Gy in 30 fractions. The primary tumor was boosted to 69 Gy. A comparison anatomic plan was generated for each patient. Feasibility was met if FLA plans (compared with anatomic plans) allowed (1) a reduction in functional mean lung dose of ≥2% and a reduction in the functional lung volume receiving 20 Gy (fV20Gy) of ≥4%, and (2) a mean heart dose ≤30 Gy and relative heart volume receiving 50 Gy of <25%.
Results:
In total, 19 patients were recruited; 1 withdrew consent. Eighteen patients underwent chemoradiation with FLA. Of the 18 patients, 15 met criteria for feasibility. All patients completed the entire course of chemoradiation therapy. Using FLA resulted in an average reduction of the functional mean lung dose of 12.4% (SD, ±12.8%) and a mean relative reduction of the fV20Gy of 22.9% (SD, ±11.9%). At 12 months, Kaplan-Meier estimates for overall survival were 83% (95% CI, 56%-94%) and estimates for progression-free survival were 50% (95% CI, 26%-70%). Quality-of-life scores were stable across all time points.
Conclusions:
Using 68Ga-4D-V/Q PET/CT to image and avoid functional lung is feasible.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:44Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...