Related Experiment Video
Updated: Jul 28, 2025

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Separation and identification of different therapeutic pharmaceutical drugs on humic acid-based HPLC column: Method
Hamide Filiz Ayyildiz1, Fakhar N Memon2, Irfan Ali Mangi2
1Department of Basic Pharmaceutical Sciences, Faculty of Pharmacy, Selçuk University, Konya, Turkey.
Abstract:
Multimode chromatographic separations are highly desirable in pharmaceutical and environmental sciences. Current study deals with the application of newly developed mixed-mode end capped-immobilized humic acid onto an aminopropyl silica based chromatographic column for separation and identification of six drugs belonging to different therapeutic groups for its applicability in pharmaceutical industries. For this, central composite design was used to evaluate the separation and resolution by optimization of three most effective parameters (acetonitrile%, flow rate, and pH of mobile phase). Second-order quadratic model was used to evaluate their effect on resolution of peaks; the probability value (<0.05) obtained from analysis of variance suggested the best applicability of the model. Desirability function was applied to calculate optimum conditions (44.8% acetonitrile, 1.75 mL/min of flow rate, and 7.5 pH) required to achieve maximum separation with good resolution within 11 min. The method was validated for linearity, precision accuracy, selectivity, and sensitivity. The results revealed a highly precise (coefficient of variance > 1%), linear (R2 = 0.99), and highly selective method. Moreover, the limit of detection/quantification values revealed acceptable sensitivity of the method. The developed column was compared for its efficiency with a commercially available column and found to be highly applicable for industrial applications.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...