Electrochemical immunoassay for one-pot detection of thyroxin (T4) and thyroid-stimulating hormone (TSH) using magnetic and Janus nanoparticles
Related Experiment Video
Updated: Jul 28, 2025

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Pari Karami1, Danial Gholamin2, Mohammad Johari-Ahar3,4
1Biosensor Sciences and Technologies Research Center, Ardabil University of Medical Sciences, Ardabil, Iran.
Abstract:
Concurrent measurement of thyroid-stimulating hormone (TSH) and thyroxine (T4) hormones profoundly help clinicians diagnose hyper- and hypothyroidism. This work demonstrates the development of a sandwich-type electrochemical immunoassay using Janus and magnetic nanoparticles for one-pot detection of thyroxine (T4) and thyroid-stimulating hormone (TSH). The signaling probe was developed by preparing Janus cadmium (CdO) and zinc oxide (ZnO) NPs decorated by T4/TSH-specific molecularly imprinted polymers (MIPT4-CdO and MIPTSH-ZnO). The capture probe was obtained by coating magnetic Fe3O4 NPs with 1,3-Bis(3-carboxy propyl) tetramethyl disiloxane and activating using N-hydroxy succinimide (NHS) and 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC), and finally conjugating with T4/TSH-specific antibodies. To analyze T4 and TSH in actual samples, MIPT4-CdO and MIPTSH-ZnO were added to the sample solutions, and after incubation, capture probes (Fe3O4-AbTSH and Fe3O4-AbT4) were added. An external magnetic field was used to separate the sandwiched nanosystem, followed by adding a dilute solution of nitric acid (HNO3) to dissolve CdO and ZnO NPs and free Cd(II) and Zn(II) cations. The concentration of these cations was determined using constant-current potentiometric stripping analysis (cc-PSA) on screen-printed electrodes (SPE) modified with multi-walled carbon nanotubes (MWCNT). The obtained signals for Cd(II) and Zn(II) were proportional to T4 and TSH concentrations. Limits of detection (LOD) for T4 and TSH analyses were respectively 0.02 ng.dL-1 and 0.0002 µU.mL-1 with a linear range of 0.05-50 ng.dL-1 and 0.001-100 µU.mL-1. The proposed nanosystem's main advantage is the simultaneous detection of T4 and TSH in clinical samples with high sensitivity, selectivity, and stability.
More Related Videos
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
Published on: June 23, 2022
06:58Rapid Homogeneous Detection of Biological Assays Using Magnetic Modulation Biosensing System
Published on: June 13, 2010