Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
Published on: March 19, 2021
Optimization technique for increasing resolution in computed tomography imaging
I V Grossu1, O Savencu2, M Verga3
1Coltea Clinical Hospital, I.C. Bratianu 1, Bucuresti 030171, Romania.
Abstract:
Starting from the importance of conforming to biological reality in medicine, in this paper we propose an optimization technique for increasing resolution of computed tomography (CT) images acquired using various existing scanners. Considering a three-dimensional Hounsfield Units (HU) array, together with the corresponding spatial metadata of interest (pixel sizes and slice thickness), the procedure is based on halving each voxel along the directions of the device's Cartesian frame of reference and find those values which are both satisfying the X-Rays attenuation coefficient average requirement and minimizing the HU distance to classical interpolation points. The discussed method was tested by implementing a C# .Net 6, cross-platform library containing two algorithm flavors that could be independently applied: "Z" for doubling the number of slices, and "XY" for doubling the resolution of individual slices. This design allows also chaining (e.g. one could apply the "Z,XY,Z" sequence in order to reduce four times slice thickness). In the context of existing unavoidable limitations, the first results are suggesting the "CT compatible" interpolation technique could provide a reasonable approximation of reality. However, the main advantage comes from satisfying mass conservation, which is of high importance in medical diagnosis and treatment.•The Hounsfield Units scale is defined as a linear transformation of the X-Rays attenuation coefficients. Thus, splitting a computed tomography voxel into two congruent volumes must satisfy the HU average requirement (the initial value must equal the average of the two output HU values).•Existing interpolation methods (linear, spline, etc.) are not compatible with the computed tomography HU average requirement. This could also result in mass estimate anomalies with significant impact in medical diagnosis.•The proposed "CT compatible" interpolation method is based on finding those values which are both satisfying the X-Rays attenuation coefficient average requirement and minimizing the Hounsfield Units distance to classical interpolation points.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...