Related Experiment Video
Updated: Jul 28, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Screening strategy for 1210 exogenous chemicals in serum by two-dimensional liquid chromatography-mass spectrometry
Yuting Wang1, Lina Zhou2, Tiantian Chen1
1CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Abstract:
Humans are at risk of exogenous exposure to exogenous chemicals. Challenges exist for the comprehensive monitoring of residues with different physical and chemical properties in serum. Here, an on-line two-dimensional liquid chromatography (2D-LC) - high resolution mass spectrometry system (HRMS) was developed, expanding the range of the partition coefficient in octanol/water of the residue analysis from -8 to 12. A high-coverage serum residue screening strategy was further designed by integrating 2D-LC system with HRMS full MS/data independent acquisition and automatic spectral library searching. This strategy enables to simultaneously screen 1210 pesticides, veterinary/human drugs, other chemical pollutants and their metabolites in serum with a single analysis. Method validation showed 92% and 81% of 1022 residues spiked in serum could be detected at 50 ng/mL and 5 ng/mL, respectively. The developed method was applied to the analysis of 24 separately pooled serum samples, 58 suspect residues were found, some of them were detected at high frequencies over than 50%. Among them, 4,6-Dinitro-O-cresol and probable carcinogenic folpet are highly toxic, and cimaterol is banned in China. Collectively, this study developed a 2D-LC-HRMS -based screening strategy for screening pesticides, veterinary/human drugs, and other chemical pollutants in serum, it is helpful for studying the effect of exogenous exposures on human health.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...