Related Experiment Video
Updated: Jun 18, 2026

High Speed Droplet-based Delivery System for Passive Pumping in Microfluidic Devices
Published on: September 2, 2009
Comparison of the Sensor-Augmented Pump System with the Advanced Hybrid Closed-Loop Delivery System: Quality of Life,
Emmanouil S Benioudakis1, Eleni Karlafti1, Argyroula Kalaitzaki2
1Diabetes Center, 1st Propaedeutic Department of Internal Medicine, Medical School, "AHEPA" General University Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Background:
Type 1 diabetes mellitus (T1D) is a chronic disease that requires exogenous insulin administration and intensive management to prevent any complications. Recent innovations in T1D management technologies include the Advanced Hybrid Closed-Loop delivery system (AHCL). The pioneer AHCL system provides automated basal and automated bolus corrections when needed.
Objective:
This study aimed to compare the Advanced Hybrid Closed-Loop (AHCL) system and the Sensor-Augmented Pump (SAP) with Predictive Low Glucose Management (PLGM) system, in relation to glycaemic outcomes, general and diabetes-related Quality of Life (QoL), and diabetes distress.
Methods:
General and diabetes-related QoL were assessed with the Diabetes Quality of Life Brief Clinical Inventory (DQOL-BCI) and the World Health Organization Quality of Life-BREF (WHOQOL-BREF), respectively. Diabetes distress was assessed with the Diabetes Distress Scale for Type 1 diabetes (T1-DDS).
Results:
Eighty-nine T1D adults participated in the study, mostly females (65.2%), with a mean age of 39.8 (± 11.5 years). They had on average 23 years of diabetes (± 10.7) and they were on continuous subcutaneous insulin infusion therapy. Significant differences favoring the AHCL over the SAP + PLGM system were demonstrated by lower mean glucose levels, less time above range, lower scores on DQOL-BCI, T1-DDS, and higher scores on WHOQOL-BREF. Finally, the linear regression models revealed the association of time in range in most of the above aspects.
Conclusion:
This study highlighted the advantages of the AHCL system over the SAP + PLGM system in the real-world setting in relation to general and diabetes-related QoL, diabetes distress, and glycaemic outcomes.