Related Experiment Video
Updated: Jul 28, 2025

Assessment of Viability of Human Fat Injection into Nude Mice with Micro-Computed Tomography
Published on: January 7, 2015
CT volumetry study of microfat graft survival from different donor sites in augmenting the enophthalmic socket
Aliaa A Farag1, Haytham E Nasr1, Tamer I Gawdat1
1Ophthalmology Department, Kasr Al Ainy Hospital, Cairo University, Cairo, Egypt.
Purpose:
To evaluate autologous fat grafts harvested from the abdomen versus the thigh for treating the enophthalmic socket using CT volumetry.
Methods:
A randomized prospective interventional study including 20 patients suffering from unilateral enophthalmic socket. Pre-operative clinical assessment included photographs, exophthalmometry reading as well as CT volumetry for volume deficit calculations and the harvesting site was randomly allocated (abdomen or thigh). All patients completed 6 months of follow-up. Exophthalmometry change and percentage of retained fat with the globe included and without it at follow-up were measured.
Results:
Microfat graft survival showed no statistically significant correlation with sex, age, or donor site. Mean percentage of retained fat with globe and without it were 14.75% and 25.31%, respectively. Difficulty of extraction and degree of volume deficit correlated significantly with percentage of fat retained. Exophthalmometer change correlated significantly with percentage of fat retained.
Conclusion:
Autologous fat grafting is a safe and effective technique for volume augmentation of enophthalmic sockets regardless of its harvesting site. CT volumetry has an important role in accurately measuring the volume deficit as well as the postoperative results.