Related Experiment Video
Updated: Jul 28, 2025

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Remodeling of the cardiovascular hemodynamic environment by lower limb heat exposure: A computational fluid dynamic
Zhongyou Li1, Xiao Li1, Fei Yan2
1Sichuan Province Biomechanical Engineering Laboratory, Chengdu, China; Department of Mechanical Science and Engineering, Sichuan University, Chengdu, China.
Background:
Lower limb heat exposure (LLHE) is a promising strategy for the daily management of cardiovascular health because of its non-pharmaceutical advantages. To support the application of this strategy in cardiovascular protection, we examined its impact on the global hemodynamic environment.
Methods:
Skin blood flow (SBF) of eight locations on the lower limbs was measured before and after LLHE (40 °C and 44 °C) in ten healthy subjects by using a laser Doppler flowmeter. A closed-loop model of circulation uses changes in SBF to quantify the influence of LLHE on the blood flow of the arterial trunk (from ascending aorta to the femoral artery) and visceral branches (coronary, celiac, renal, and mesenteric arteries).
Results:
The SBF in all locations tested on the lower limbs increased significantly (p<0.001) with LLHE and a 3.39-fold and 7.40-fold increase in mean SBF were observed under 40 °C and 44 °C conditions, respectively. In the model, the peak (3.9-25.1%), end-diastolic (13.7-107.3%), and mean blood flow (8.5-86.5%) in the arterial trunk increased with the increase in temperature, but the retrograde flow in the thoracic aorta and abdominal aorta Ⅰ increased at least twice in the diastolic period. Furthermore, LLHE also increased the blood flow of the visceral branches (2.5-20.7%).
Conclusion:
These findings suggest that LLHE is expected to be a daily strategy for enhancing the functions of both the arterial trunk and visceral arteries, but the increased blood flow reversal in the thoracic and abdominal aortas warrants further investigation.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease IV: Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

