Related Experiment Video
Updated: Jul 28, 2025

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Effect of different titration methods on right heart function and prognosis in patients with acute respiratory
Daoran Dong1, Chengqiao Jing1, Yuan Zong1
1Department of ICU, Shaanxi Provincial People's Hospital, Xi'an, China.
Background:
Acute respiratory distress syndrome (ARDS) is a common disease in intensive critical care(ICU), and the use of positive end-expiratory pressure(PEEP) during mechanical ventilation can increase the right heart afterload and eventually cause right heart dysfunction. For these factors causing acute cor pulmonale(ACP), especially inappropriate mechanical ventilation settings, it is important to explore the effect of PEEP on right heart function.
Objective:
To investigate the effects of three titration methods on right heart function and prognosis in patients with ARDS.
Methods:
Observational, prospective study in which ARDS patients were enrolled into three distinct PEEP-titration strategies groups: guide, transpulmonary pressure-oriented and driving pressure-oriented. Prognostic indicators, right heart systolic and diastolic echocardiographic function indices, ventilatory parameters, blood gas analysis results, and respiratory mechanics Monitoring indices were collated and analyzed statistically by STATA 15 software.
Results:
A total of 62 ARDS patients were enrolled into guide (G) group (n=40) for whom titrated PEEP values were 9±2cm H2O, driving pressure-oriented (DPO) group (n=12) with titrated PEEP values of 10±2cm H2O and transpulmonary pressure-oriented (TPO) group (n=10) with titrated PEEP values of 12±3cm H2O. Values were significantly higher for TPO than for G (p=0.616) or DPO (p=0.011). Compliance was significantly increased after 72 h in the TPO and DPO groups compared with the G group (p<0.001). Mean airway pressure at end-inspiratory obstruction (p=0.047), tricuspid annular plane systolic excursion (TAPSE, p<0.001) and right ventricular area change fraction (RVFAC, p=0.049) were all higher in the TPO and DPO groups than in the G group. E/A indices were significantly better in the TPO group than in the G or DPO groups (p=0.046). No significant differences in 28 day mortality were found among the three groups. Multivariate logistic regression analysis revealed that lung compliance and transpulmonary pressure-oriented PEEP titration method was negatively correlated to the increase in right ventricular systolic dysfunction.
Conclusion:
Transpulmonary pressure-oriented PEEP titration improves oxygenation and pulmonary function and causes less right heart strain when compared to other PEEP-titration methods during mechanical ventilation of ARDS patients.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Heart Failure VI: Adjunct Therapies
Heart Failure V: Medical Management
Heart Failure II: Pathophysiology