Adverse Event Causes From 2022 for Four Continuous Glucose Monitors.
1Krouwer Consulting, Sherborn, MA, USA.
Journal of Diabetes Science and Technology
|June 2, 2023
Summary
Continuous glucose monitors (CGMs) had 281,963 adverse events in 2022. Analyzing these events by cause helps reduce future issues for people with diabetes.
Area of Science:
- Medical Devices
- Diabetes Technology
- Patient Safety
Background:
- Continuous glucose monitors (CGMs) are crucial for diabetes management.
- A significant number of adverse events (281,963 in 2022) are associated with CGMs.
- Understanding these adverse events is vital for improving patient safety.
Purpose of the Study:
- To review the process of obtaining CGM adverse event data.
- To analyze the causes of adverse events reported to the US Food and Drug Administration (FDA).
- To identify common and device-specific causes of CGM malfunctions and injuries.
Main Methods:
- Adverse events for four major CGM products were extracted from the FDA database.
- Data was organized using SQL Server, categorizing events by malfunction or injury.
- Causes were determined by analyzing the text descriptions of adverse events, not solely relying on manufacturer codes.
Main Results:
- Common causes included events preventing users from obtaining readings and device inaccuracy.
- Specific causes varied depending on the particular CGM device.
- Analysis revealed a need to look beyond manufacturer codes to understand root causes.
Conclusions:
- Structuring CGM adverse event data by manufacturer and event type, followed by text analysis, aids in identifying causes.
- Analyzing adverse event data is a critical first step toward mitigating issues.
- This systematic approach can lead to improved safety and reliability of CGMs for individuals with diabetes.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
2.6K
Type 2 diabetes, characterized by insulin resistance, arises when the insulin receptors on cells lose responsiveness to insulin, diminishing the cell's capacity to take up glucose, resulting in elevated blood glucose levels. To receive a diagnosis of Type 2 diabetes, a series of blood glucose tests are necessary to assess whether the blood glucose falls within normal parameters. If the result is out of the normal range, a patient may be diagnosed as prediabetic or diabetic, depending on the...
2.6K
Dipeptidyl Peptidase 4 Inhibitors
216
Dipeptidyl peptidase 4 (DPP-4) is a serine protease widely distributed in the body. It's involved in the inactivation of GLP-1 and GIP hormones, which are crucial for insulin regulation. DPP-4 inhibitors, such as sitagliptin (Januvia), saxagliptin (Onglyza), linagliptin (Tradjenta), alogliptin (Nesina), and vildagliptin (Galvus), help increase the proportion of active GLP-1, enhancing insulin secretion. These inhibitors work by competitively binding to DPP-4. This binding causes a...
216
Hypoglycemia and Glucagon
306
Without prolonged fasting, healthy individuals maintain blood glucose levels above 3.5 mM due to a well-adapted neuroendocrine counterregulatory system that effectively prevents acute hypoglycemia, a potentially life-threatening condition. The primary clinical scenarios for hypoglycemia encompass diabetes treatment, inappropriate production of endogenous insulin or insulin-like substances by tumors, and the use of glucose-lowering agents in non-diabetic individuals. Notably, hypoglycemia in the...
306
Errors occurring during blood pressure monitoring
798
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
798
Holter Monitor: 24-Hour Monitoring
73
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
73
Diabetes: Symptoms, Diagnosis, and Complications
606
For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
606