Related Experiment Video
Updated: Jul 28, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
A novel breakthrough in wrist-worn transdermal troponin-I-sensor assessment for acute myocardial infarction
Shantanu Sengupta1, Siddharth Biswal2, Jitto Titus2
1Sengupta Hospital and Research Institute, Nagpur- 440033, Vidarbha (Dist), India.
Aims:
Clinical differentiation of acute myocardial infarction (MI) from unstable angina and other presentations mimicking acute coronary syndromes (ACS) is critical for implementing time-sensitive interventions and optimizing outcomes. However, the diagnostic steps are dependent on blood draws and laboratory turnaround times. We tested the clinical feasibility of a wrist-worn transdermal infrared spectrophotometric sensor (transdermal-ISS) in clinical practice and assessed the performance of a machine learning algorithm for identifying elevated high-sensitivity cardiac troponin-I (hs-cTnI) levels in patients hospitalized with ACS.
Methods And Results:
We enrolled 238 patients hospitalized with ACS at five sites. The final diagnosis of MI (with or without ST elevation) and unstable angina was adjudicated using electrocardiography (ECG), cardiac troponin (cTn) test, echocardiography (regional wall motion abnormality), or coronary angiography. A transdermal-ISS-derived deep learning model was trained (three sites) and externally validated with hs-cTnI (one site) and echocardiography and angiography (two sites), respectively. The transdermal-ISS model predicted elevated hs-cTnI levels with areas under the receiver operator characteristics of 0.90 [95% confidence interval (CI), 0.84-0.94; sensitivity, 0.86; and specificity, 0.82] and 0.92 (95% CI, 0.80-0.98; sensitivity, 0.94; and specificity, 0.64), for internal and external validation cohorts, respectively. In addition, the model predictions were associated with regional wall motion abnormalities [odds ratio (OR), 3.37; CI, 1.02-11.15; P = 0.046] and significant coronary stenosis (OR, 4.69; CI, 1.27-17.26; P = 0.019).
Conclusion:
A wrist-worn transdermal-ISS is clinically feasible for rapid, bloodless prediction of elevated hs-cTnI levels in real-world settings. It may have a role in establishing a point-of-care biomarker diagnosis of MI and impact triaging patients with suspected ACS.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation