Interrater and intrarater reliability of four different classification methods for evaluating acromial morphology on
Thomas W Mayntzhusen1, Adam Witten1, Jens Gramkow1
1Sports Orthopedic Research Center - Copenhagen (SORC-C), Department of Orthopedic Surgery, Copenhagen University Hospital, Amager-Hvidovre, Denmark.
Background:
Acromial morphology is an important pathophysiological factor for the development of subacromial impingement syndrome. There are 3 radiological methods to evaluate acromial morphology: Bigliani, modified Epstein, and acromial angle. However, their reliability have not been compared in a single study, nor using standardized radiographs. Consequently, the evaluation of acromial morphology is currently not validated though its widespread use across the world. The objective of this study was to investigate reliability of the 3 known classifications and the novel Copenhagen Acromial Curve classification.
Methods:
Three experienced clinicians rated 102 standardized supraspinatus outlet view radiographs with the 4 classification methods in 2 separate sessions a month apart. All measurements were blinded. With an expected kappa () and intraclass correlation coefficient (ICC) > 0.7 (+/-0.15), the target sample size was 87 radiographs.
Results:
The Bigliani classification had interrater and intrarater reliability ranging from fair to good (κ 0.32-0.41 and 0.26-0.62). The modified Epstein classification had fair to good interrater and intrarater reliability (κ 0.24-0.69 and 0.57-0.63). The acromial angle classification had moderate to good interrater and intrarater reliability (κ 0.53-0.60 and 0.59-0.72). The novel Copenhagen Acromial Curve classification showed moderate to good interrater and intrarater reliability (ICC 0.66-0.71 and 0.75-0.78, respectively).
Conclusion:
The Copenhagen Acromial Curve was the only classification method with an ICC value > 0.7. The popular Bigliani classification had the worst reliability. The Copenhagen Acromial Curve classification produces numerical data, as opposed to the other 3 classification methods. This could potentially be utilized in future research to establishing cut-off values for treatment stratification.
Related Concept Videos
Classification of Bones
Long and Short Bones
The appendicular skeleton, particularly the upper and lower limbs, is primarily made of long and short bones. The...
Functional Classification of Joints
The functional classification of joints is determined by the amount of mobility between the adjacent bones. Joints are functionally classified as a synarthrosis or immobile joint, an amphiarthrosis or slightly moveable joint, or as a diarthrosis, a freely moveable joint. Fibrous and cartilaginous joints can be functionally classified as either synarthroses or amphiarthroses, whereas all synovial joints are classified as diarthroses.
Synarthrosis
An...
Receiver Operating Characteristic Plot