Related Experiment Video
Updated: Jul 28, 2025

Generic Protocol for Optimization of Heterologous Protein Production Using Automated Microbioreactor Technology
Published on: December 15, 2017
Multivariate optimization of characteristic parameters of continuous-flow system with a front buffer tank for
Shida Li1, Fantang Zeng1, Shaokui Zheng2
1The Key Laboratory of Water and Air Pollution Control of Guangdong Province, South China Institute of Environmental Sciences, Ministry of Ecology and Environment, No. 18 Ruihe Road, Guangzhou, 510530, China.
Abstract:
Industrial reverse osmosis concentrate (ROC) was electrochemically oxidized using a continuous-flow system (CFS) with a front buffer tank. Multivariate optimization including Plackett-Burman (PBD) and central composite design based on response surface method (CCD-RSM) was implemented to investigate the effects of characteristic (e.g., recirculation ratio (R value), ratio of buffer tank and electrolytic zone (RV value)) and routine (e.g., current density (i), inflow linear velocity (v) and electrode spacing (d)) parameters. R, v values and current density significantly influenced chemical oxygen demand (COD) and NH4+-N removal and effluent active chlorine species (ACS) level, while electrode spacing and RV value had negligible effects. High chloride content of industrial ROC facilitated the generation of ACS and subsequent mass transfer, low hydraulic retention time (HRT) of electrolytic cell improved the mass transfer efficiency, and high HRT of buffer tank prolonged the reaction between the pollutants and oxidants. The significance levels of COD removal, energy efficiency, effluent ACS level and toxic byproduct level CCD-RSM models were validated by statistical test results, including higher F value than critical effect value, lower P value than 0.05, low deviation between predicted and observed values, and normal distribution of calculated residuals. The highest pollutant removal was achieved at a high R value, a high current density and a low v value; the highest energy efficiency was achieved at a high R, a low current density and a high v value; the lowest effluent ACS and toxic byproduct levels were achieved at a low R value, a low current density and a high v value. Following the multivariate optimization, the optimum parameters were decided to be v = 1.2 cm h-1, i ≥ 8 mA cm-2, d ≥ 4, RV = 10-20 and R = 1 to achieve better effluent quality (i.e., lower effluent pollutant, ACS and toxic byproduct levels).
Related Concept Videos
Solution Concentration and Dilution
Osmosis and Osmotic Pressure of Solutions
Pipe Flowrate Measurement: Problem Solving
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures...

