Related Experiment Video
Updated: Jul 28, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Comprehensive characterization of volatile and semi-volatile compounds in e-liquids for electronic cigarette using
M Cobo Golpe1, M Ramil1, I Rodríguez1
1Department of Analytical Chemistry, Nutrition and Food Sciences. Research Institute on Chemical and Biological Analysis (IAQBUS). Universidade de Santiago de Compostela, 15782-Santiago de Compostela, Spain.
Abstract:
The consumption of electronic cigarettes is a habit with an increasing prevalence, particularly among youths. Knowing the composition of e-liquids used in these devices represents the first step to understand the potential impact of e-smoking in the health of consumers. Herein, a non-target screening methodology was applied to the identification of volatile and semi-volatile compounds in a set of e-liquids from different suppliers, with different flavors, and containing different kinds of additives, such as nicotine or cannabidiol. To this end, samples were characterized by gas chromatography accurate mass spectrometry, using a time-of-flight mass analyzer. Combination of deconvoluted electronic ionization mass spectra with linear retention index values, obtained for two columns with different selectivity, permitted the identification of more than 250 chemicals with different confidence levels. Among them, respiratory pro-inflammatory compounds, acetals of propylene glycol and glycerin with aldehydes, nicotine-related and non-related alkaloids, and psychoactive cannabinoids were confirmed as concerning compounds in e-liquid samples. Concentration ratios between propylene glycol acetals and parent aldehydes varied in the range from 2% (ethyl vanillin) to more than 80% (case of benzaldehyde). The ratios between the concentrations of delta-9-tetrahydrocannabinol and cannabidiol in e-liquids stayed in the range from 0.02% to 0.3%.
More Related Videos
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...