Atomic imaging with a 12 T magnetic field perpendicular or parallel to the sample surface by an ultra-stable scanning
Jihao Wang1, Weixuan Li1, Wenjie Meng1
1Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, Chinese Academy of Sciences, Hefei, Anhui 230031, China; The High Magnetic Field Laboratory of Anhui Province, Hefei, Anhui 230031, China.
Abstract:
We present the first nonmetallic scanning tunneling microscope (STM) featuring an ultra-stable tip-sample mechanical loop and capable of atomic-resolution imaging within a 12 T magnetic field that could be either perpendicular or parallel to the sample surface. This is also the first STM with an ultra-stable tip-sample mechanical loop but without a standalone scanner. The STM head is constructed only with two parts: an improved spider-drive motor and a zirconia tip holder. The motor performs both the coarse approach and atomic imaging. A supporting spring is set at the fixed end of the motor tube to decrease the tip-sample mechanical loop. The zirconia tip holder performs as the frame of the whole STM head. With the novel design, the STM head in three dimensions can be as small as 7.9 mm × 7.9 mm × 26.5 mm. The device's excellent performance is demonstrated by atomic-resolution images of graphite and NbSe2 obtained at 300 K and 2 K, as well as the high-resolution dI/dV spectrums of NbSe2 at variable temperatures. Low drift rates in the X-Y plane and Z direction further prove the imaging stability of our new STM. High-quality imaging of the Charge Density Wave (CDW) structure on a TaS2 surface shows the STM's good application capability. Continuous atomic images obtained in magnetic fields rangs from 0 T to 12 T with the direction of the magnetic field perpendicular or parallel to the sample surface show the STM's good immunity to high magnetic fields. Our results illustrate the new STM's broad application ability in extreme conditions of low temperature and high magnetic field.
More Related Videos
11:33All-electronic Nanosecond-resolved Scanning Tunneling Microscopy: Facilitating the Investigation of Single Dopant Charge Dynamics
Published on: January 19, 2018
07:42Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains
Published on: July 20, 2022
Related Concept Videos
Overview of Microscopy Techniques
Magnetic Resonance Imaging
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...