Xu Xiong1,2, Ya-Ling Chen3, Lan Zhao1
1Department of Orthopedic Surgery, The 908th Hospital of the Chinese People's Liberation Army Joint Logistics Support Forces, No.1028 Jinggangshan Avenue, Qingyunpu District, Nanchang, 330006, Jiangxi Province, People's Republic of China.
Purpose:
3D printing techniques guide precision medicine and show great development potential in clinical applications. The purpose of this study was to compare the clinical outcomes of 3D-printed navigation templates versus free-hand in tension band wiring (TBW) procedures for olecranon fractures.
Methods:
Patients who underwent TBW due to Mayo type II olecranon fractures between January 2019 and December 2021 in our hospital were prospectively enrolled in the study. The patients were divided into the 3D printed navigation template guiding TBW group (3D printed group) and the free-hand TBW group (free-hand group). The primary endpoint of this study was the success rate of the bicortical placement of Kirschner wires (K-wires). Times of intraoperative fluoroscopy, operation times, complications, VAS scores, and Mayo Elbow Performance Scores (MEPS) were analyzed as the secondary outcomes measure.
Results:
The success rate of the bicortical placement of K-wires was 85.7% in the 3D Printed group was significantly higher than the free-hand group (60%). There were fewer times of intraoperative fluoroscopy in the 3D Printed group (1.43 ± 0.51) than that in the free-hand group (2.60 ± 1.00) with statistical significance (P < 0.05). At the date of the last follow-up, four patients suffer from pain and skin injury at the K-wires insertion site in the 3D Printed group and 14 patients in the free-hand group, a significant difference between the two groups (P < 0.05). No statistically significant differences were found in operation time, VAS scores, and MEPS between the two groups.
Conclusions:
The individualized 3D-printed navigation template-assisted TBW demonstrated good accuracy and resulted in reduced times of intraoperative fluoroscopy and complication compared to the free-hand TBW for olecranon fractures.