Initial experience of coaxial percutaneous liver biopsy with tract embolization using
Yohsuke Suyama1, Shigeyoshi Soga1,2, Ayako Mikoshi1
1Department of Radiology, National Defense Medical College, Saitama, Japan.
Objective:
Bleeding occurs after liver biopsy in up to 10.9% cases, and patients with impaired hemostasis or ascites are considered to have absolute or relative contraindications. N-butyl cyanoacrylate enables immediate hemostasis, even in lethal situations. Therefore, percutaneous liver biopsy combined with tract embolization using N-butyl cyanoacrylate is expected to enable safe biopsy, even in patients for whom conventional biopsy is contraindicated. Here we describe our initial experience with coaxial percutaneous biopsy with tract embolization using N-butyl cyanoacrylate.
Materials And Methods:
Eighty-six patients who underwent tract embolization using N-butyl cyanoacrylate between October 2014 and July 2020, including 21 patients who had absolute or relative contraindications for liver biopsy, were retrospectively analyzed. Tract embolization using N-butyl cyanoacrylate comprised two steps: (1) liver biopsy with a biopsy needle inserted via a coaxial introducer needle and (2) embolization of the puncture route by injecting N-butyl cyanoacrylate via the coaxial needle.
Results:
No complications occurred in any patient. The mean number of biopsies per patient was 3.30 (range, 1-7). Histologically adequate samples were acquired in all cases, and pathological diagnoses were obtained. The mean time required for tract embolization was 52.8 s (range, 6-132 s). The mean peak skin dose was 9.97 mGy (range, 2-68 mGy), which is far below the 3-Gy threshold dose for temporary erythema.
Conclusions:
This proposed technique may be a promising and straightforward alternative to improve the management of patients with severe liver disease by allowing safer biopsy, including patients for whom conventional liver biopsy is contraindicated.