Related Experiment Video
Updated: Jul 27, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Comparison between LMA ProSeal and I-gel airway in anesthetized patients on spontaneous ventilation during daycare
Hemlata1, Neha Singh1, Ajay K Chaudhary1
1Department of Anaesthesiology, KGMU, Lucknow, Uttar Pradesh, India.
Background:
General anesthesia remains the most popular technique for ambulatory surgeries with patients, surgeons, and anesthesia providers. The supraglottic airway (SGA) devices result in fewer incidences of sore throat, laryngospasm, coughing, and hoarseness as compared to inserting a tracheal tube. This study was conducted to compare two second-generation SGA devices, LMA ProSeal and I-gel airway, in anesthetized patients on spontaneous ventilation during daycare procedures to establish the superior SGA device.
Methodology:
This prospective randomized study was done on 90 patients of either sex aged 15-60 years, ASA grade I-II, Mallampatti grade I and II, and BMI between 20 and 30 kg/m2 scheduled for elective surgeries of duration less than 90 min. Patients were randomly allocated into two groups-group A (I-gel) and group B (LMA ProSeal). Insertion parameters, hemodynamic responses, oxygenation, ventilation, peak airway pressure (PAP), and postoperative complications were recorded. Statistical analysis was done using SPSS version 21.0 statistical analysis software.
Results:
Mean insertion time of LMA ProSeal was found to be significantly higher as compared to I-gel (33.27 ± 3.88 vs 18.49 ± 3.18 s; P < 0.001). No significant difference was found between the groups in the number of attempts and of operators attempted for insertion, as well as in hemodynamic response, oxygenation, and ventilation. Postoperative complications were lesser in group A.
Conclusion:
I-gel is an easy-to-insert cuffless SGA device requiring lesser time for insertion, provides adequate ventilation with lesser postoperative complications and thus appears to be better than LMA ProSeal.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...