Related Experiment Video
Updated: Jul 27, 2025

Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Unilateral transfemoral osseointegrated prostheses improve joint loading during walking
Nicholas W Vandenberg1, Jason W Stoneback2, Hope Davis-Wilson3
1Department of Mechanical Engineering, University of Colorado Denver, Denver CO, United States.
Abstract:
People with unilateral transfemoral amputation using socket prostheses are at increased risk for developing osteoarthritis in both the residual hip and intact lower-limb joints. Osseointegrated prostheses are a surgical alternative to socket prostheses that directly attach to the residual femur via a bone-anchored implant, however their multi-joint loading effect is largely unknown. Our objective was to establish how osseointegrated prostheses influence joint loading during walking. Motion capture data (kinematics, ground reaction forces) were collected from 12 participants at baseline, with socket prostheses, and 12-months after prosthesis osseointegration during overground walking at self-selected speeds. Subject-specific musculoskeletal models were developed at each timepoint relative to osseointegration. Internal joint moments were calculated using inverse dynamics, muscle and joint reaction forces (JRFs) were estimated with static optimization. Changes in internal joint moments, JRFs, and joint loading-symmetry were compared using statistical parametric mapping (p≤ 0.05) before and after osseointegration. Amputated limb hip flexion moments and anterior JRFs decreased during terminal stance (p = 0.002, <0.001; respectively), while amputated limb hip abduction moments increased during mid-stance (p < 0.001), amputated hip rotation moment changed from internal to external throughout early stance (p < 0.001). Intact limb hip extension and knee flexion moments (p = 0.028, 0.032; respectively), superior and resultant knee JRFs (p = 0.046, 0.049; respectively) decreased during the loading response following prosthesis osseointegration. These results may indicate that the direct loading transmission of these novel prostheses create a more typical mechanical environment in bilateral joints, which is comparable with loading observed in able-bodied individuals and could decrease the risk of development or progression of osteoarthritis.
More Related Videos
08:08Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
11:16Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Related Concept Videos
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Ankle Joint
Bones of the Lower Limb: Femur and Patella
Bones of the Lower Limb: Tibia and Fibula
Development of the Limb Synovial Joints
The mesenchymal stem cells differentiate into chondrocytes that form the hyaline cartilage, and later the cartilaginous model of the bone. This model further transforms into a bone. This process is known as endochondral ossification.
During development, the limbs...