Real-World User and Clinician Perspective and Experience with MiniMed 780G Advanced Hybrid Closed Loop System

Jothydev Kesavadev1, Anjana Basanth2, Gopika Krishnan2

  • 1Jothydev's Diabetes Research Center, JDC Junction, Mudavanmugal, Trivandrum, Kerala, 695032, India. jothydev@gmail.com.

Summary

The advanced hybrid closed loop (AHCL) MiniMed™ 780G system provides excellent glycemic control for type 1 diabetes (T1DM) management, significantly reducing hypoglycemia. User satisfaction is high, though education on carb counting and system use is crucial for optimal performance.

Related Concept Videos

Insulin: Dosing Regimen and Adverse Effects01:16

Insulin: Dosing Regimen and Adverse Effects

Insulin-replacement therapy usually includes both long-acting insulin (basal) and short-acting insulin (to cater to postprandial needs). In a diverse group of type 1 diabetes patients, the average daily insulin dose is typically 0.5-0.7 units/kg body weight. However, obese patients and pubertal adolescents may need more due to insulin resistance.
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
216
Insulin Formulations: Types and Delivery01:27

Insulin Formulations: Types and Delivery

Insulin preparations are categorized by their duration of action into short-acting and long-acting types. Two strategies are used to modify insulin's absorption and pharmacokinetic profile: slowing the absorption post-subcutaneous injection, or altering human insulin's amino acid sequence or protein structure. These changes retain the insulin's ability to bind to the insulin receptor, but alter its behavior in solution or after injection.
Short-acting insulins are divided into...
238
Diabetes: Management and Pharmacotherapy01:15

Diabetes: Management and Pharmacotherapy

The therapy for diabetes aims to alleviate hyperglycemia-related symptoms, prevent acute metabolic decompensation, and reduce chronic end-organ complications. Glycemic control is evaluated through short-term (self-monitoring, continuous glucose monitoring) and long-term (A1c, fructosamine) metrics, enabling near real-time tracking of blood glucose levels and reflecting glycemic control over specific time frames.
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
319
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
42
Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
856
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
71