Real-World User and Clinician Perspective and Experience with MiniMed™ 780G Advanced Hybrid Closed Loop System
Jothydev Kesavadev1, Anjana Basanth2, Gopika Krishnan2
1Jothydev's Diabetes Research Center, JDC Junction, Mudavanmugal, Trivandrum, Kerala, 695032, India. jothydev@gmail.com.
Introduction:
The advanced hybrid closed loop (AHCL) MiniMed™ 780G system changes basal insulin delivery every 5 min and auto bolus in response to sensor glucose values. We assessed the performance of the AHCL system in real-world settings for individuals with type 1 diabetes (T1DM) as well as user and clinician perspectives and satisfaction.
Methods:
We held two peer group discussions: one having adults with T1DM/parents of children and adolescents with T1DM to understand their experiences with the AHCL system and another with healthcare providers (HCPs). Responses from the discussions were analyzed and categorized into themes by two independent researchers, with any inconsistencies resolved by consensus. We also analyzed data from the system uploaded to CareLink personal software. Glycemic outcomes, including time in range (TIR), time below range (TBR), time above range (TAR), mean sensor glucose (SG) levels, glucose management indicator (GMI), sensor use, and percentage of time spent in AHCL, were determined.
Results:
The peer group discussions revealed numerous key themes and issues for each group, such as the significance of setting reasonable expectations, carbohydrate counting and bolus dosing, technical difficulties, and overall user experience. The users (n = 25; T1DM; 17 female; age 13.8 ± 7.49 years; A1C 6.54 ± 0.45%; duration of diabetes 6 ± 6.78 years) were very satisfied with the system. Most users experienced consistent blood glucose values with very few hypoglycemic episodes. However, there were a few limitations reported, such as hyperglycemic episodes caused by inaccuracies in carb counting, issues with sensor connectivity, and cannula blockages or kinking for those using insulin Fiasp. Users achieved a mean GMI of 6.4 ± 0.26%, TIR of 83.0 ± 8.12%, TBR (54-70 mg/dL) of 2.0 ± 0.81%, TBR* (< 54 mg/dL) of 0%. All of the users achieved a TIR of > 70%.
Conclusion:
The use of the AHCL system in T1DM resulted in robust glycemic control, minimizing hypoglycemia. Providing training to both users and HCPs can help them use the system effectively.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Hemodialysis II: Procedure and Complications
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring