Related Experiment Video
Updated: Jul 27, 2025

Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
A colorimetric chemosensor for distinct color change with (E)-2-(1-(3-aminophenyl)ethylideneamino)benzenethiol to
Nilima Patil1,2, R B Dhake3, Raju Phalak1
1Department of Chemistry, D. D. N. Bhole College, Bhusawal, Jalgaon, MH, 425201, India.
Abstract:
The study reports the synthesis of chemosensor (E)-2-(1-(3-aminophenyl)ethylideneamino)benzenethiol (C1), a highly sensitive, colorimetric metal probe that shows distinct selectivity for the detection of Cu2+ ion in various real water samples. Upon complexation with Cu2+ in CH3OH/H2O (60:40 v/v) (aqueous methanol), the C1 demonstrate significant enhancement in the absorption at 250 nm and 300 nm with a color change from light yellow to brown which was visualized using naked-eye. Therefore, these properties make C1 as an effective candidate for on-site Cu2+ ions detection. The emission spectrum of C1 illustrated "TURN-ON" recognition of Cu2+ with a limit of detection (LOD) of 46 nM. Furthermore, Density Functional Theory (DFT) calculations were performed to better understand the interactions between C1 and Cu2+. The obtained results suggested that the electron clouds present around the -NH2 in nitrogen and sulfur in -SH play a pivotal role in the formation of a stable complex. The computational results were in good agreement with the experimental UV-visible spectrometry results.
More Related Videos
06:53Author Spotlight: Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
06:06Color Spot Test As a Presumptive Tool for the Rapid Detection of Synthetic Cathinones
Published on: February 5, 2018
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Complexometric Titration: Overview