Ultra-low-dose CBCT: new cornerstone of paranasal sinus imaging
P Tamminen1, J Jarnstedt2, J Numminen3
1Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland; Department of Otorhinolaryngology, Satasairaala, Pori, Finland; Department of Internal Medicine, Tampere University Hospital, Tampere, Finland; Allergy Centre, Tampere University Hospital, Tampere, Finland; Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
Background:
This study evaluates the clinical image quality (IQ) and usability of a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan. The results are compared to those of a high resolution (HR) CBCT scan to identify the strengths and weaknesses of a ULD CBCT protocol.
Methodology:
Sixty-six anatomical sites in 33 subjects were imaged twice using two imaging modalities: HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). IQ, opacification and obstruction, structural features and operative usability were assessed.
Results:
The overall IQ in subjects with 'no or minor opacification' was excellent: 100% (HR CBCT) and 99% (ULD CBCT) of ratings were evaluated as sufficient for every structure. Increased opacification reduced the quality of both imaging modalities, resulting conchtoethmoidectomy, frontal sinusotomy, sphenotomy and posterior ethmoidectomy in cases with greater opacification.
Conclusions:
IQ of paranasal ULD CBCT is sufficient for clinical diagnostics and should be considered for surgical planning. We recommend it as the primary imaging protocol for all patients who meet imaging criteria due to recurrent or chronic nasal symptoms. Additional or conventional imaging might be needed for patients with extensive chronic rhinosinusitis and/or indications of frontal sinus involvement.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography