Related Experiment Video
Updated: Jul 27, 2025

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Application of Breast Scintigraphy for Patients with Suspicious (Breast Imaging-Reporting and Data System IV) Breast
Ali Reza Azarpeikan1, Ramesh Omranipour1, Habibollah Mahmoodzadeh2
1Department of Surgical Oncology, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
Background:
The surgery for a breast imaging-reporting and data system (BIRADS) IV lesions needs imaging or pathology supporting data. The roll of breast scintigraphy for this purpose is unclear.
Materials And Methods:
In a prospective design, 16 patients with 25 BIRADS IV lesions who were scheduled for surgery were included. Before the surgery, breast scintigraphy was done using a nondedicated dual head gamma camera in the prone position employing a shaped foam pad providing imaging at breast pendulous position. Twenty mCi99m Tc methoxy-isobutyl-isonitrile was injected and two 15 and 60-min delayed imaging were done (anterior, bilateral, and single photon emission computed tomography [SPECT] projections). Pathology reports were collected and tumor to nontumor uptake ratio (T/NT) was analyzed, accordingly.
Results:
Out of all lesions, 12 were malignant (invasive ductal and lobular carcinoma ductal carcinoma in situ). At 15 min, T/NT was insignificantly higher in the malignant compared to benign lesions (22.8 ± 23.9 vs. 10.1 ± 10.1; P = 0.109). The optimal T/NT cutoff for discrimination of malignant and benign lesions was 20. Only 1 out of 13 benign lesions presented uptake >20 (7.7%; false-positive rate; P = 0.047). The diagnostic accuracy, sensitivity, and specificity for T/NT calculated at 0.68, 0.42, and 0.92, respectively. The T/NT at 60 min remained unchanged for either benign or malignant lesions (22.3 ± 30.2 vs. 11.7 ± 17.1; P = 0.296).
Conclusions:
Breast scintigraphy with general purpose gamma camera employing SPECT imaging may assist the selection of BIRADS IV lesions in need for surgery. All uptake positive cases should undergo surgery and decision for uptake negative cases should be made based on other data.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...