Related Experiment Video
Updated: Jul 27, 2025

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Safety of continuous intraoperative vagus nerve neuromonitoring during thyroid surgery
Timothy Mathieson1, Wedali Jimaja1, Frédéric Triponez1
1Department of Thoracic and Endocrine Surgery and Faculty of Medicine, University Hospitals of Geneva, Geneva, Switzerland.
Background:
Continuous intraoperative neuromonitoring has successfully demonstrated to predict impending damage to the recurrent laryngeal nerve, by detecting changes in electromyographic recordings. Despite the apparent benefits associated with continuous intraoperative neuromonitoring, its safety is still a debate. The aim of this study was to investigate the electrophysiological impact of continuous intraoperative neuromonitoring on the vagus nerve.
Methods:
In this prospective study, the amplitude of the electromyographic wave of the vagus nerve-recurrent laryngeal nerve axis was measured both proximally and distally to the stimulation electrode placed upon the vagus nerve. Electromyographic signal amplitudes were collected at three distinct events during the operation: during the dissection of the vagus nerve, before application of the continuous stimulation electrode onto the vagus nerve and after its removal.
Results:
In total, 169 vagus nerves were analysed, among 108 included patients undergoing continuous intraoperative neuromonitoring-enhanced endocrine neck surgeries. Electrode application resulted in a significant overall decrease in measured proximo-distal amplitudes of -10.94 µV (95 per cent c.i. -17.06 to -4.82 µV) (P < 0.005), corresponding to a mean(s.d.) decrease of -1.4(5.4) per cent. Before the removal of the electrode, the measured proximo-distal difference in amplitudes was -18.58 µV (95 per cent c.i. -28.31 to -8.86 µV) (P < 0.005), corresponding to a mean(s.d.) decrease of -2.50(9.59) per cent. Seven nerves suffered a loss of amplitude greater than 20 per cent of the baseline measurement.
Conclusion:
In addition to supporting claims that continuous intraoperative neuromonitoring exposes the vagus nerve to injury, this study shows a mild electrophysiological impact of continuous intraoperative neuromonitoring electrode placement on the vagus nerve-recurrent laryngeal nerve axis. However, the small observed differences are negligible and were not associated with a clinically relevant outcome, making continuous intraoperative neuromonitoring a safe adjunct in selected thyroid surgeries.
More Related Videos
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
05:12Transoral Endoscopic Thyroidectomy Vestibular Approach for Thyroid Lobectomy
Published on: May 12, 2023
Related Concept Videos
Aneurysm IV: Nursing Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Cardiomyopathy VII: Pre and Post Operative Nursing Management