Shark Fin Occlusive Myocardial Infarction ECG Pattern Post-cardiac Arrest Misinterpreted As Ventricular Tachycardia
Jose Escabi-Mendoza1, Porfirio E Diaz-Rodriguez1, Richard D Silva-Cantillo1
1Cardiology, VA Caribbean Healthcare System, San Juan, PRI.
Abstract:
In addition to the well-known convex ST-segment elevation myocardial infarction (STEMI) pattern associated with acute occlusive myocardial infarction (OMI), there are other cases that are recognized as OMI without fulfilling the established characteristic STEMI criteria. Over one-fourth of the patients initially classified as having non-STEMI can be re-classified as having OMI by recognizing other STEMI equivalent patterns. We report a case of a 79-year-old man with multiple comorbidities who was brought to the ED by paramedics with a two-hour history of ongoing chest pain. During transport, the patient suffered a cardiac arrest associated with ventricular fibrillation (VF) that required electric defibrillation and active cardiopulmonary resuscitation. Upon ED arrival, the patient was unresponsive, with a heart rate of 150 beats/min and ECG evidence of wide-QRS tachycardia that was misinterpreted as ventricular tachycardia (VT). He was further managed with intravenous amiodarone, mechanical ventilation, sedation, and unsuccessful defibrillation therapy. Upon persistence of the wide-QRS tachycardia and clinical instability, the cardiology team was emergently consulted for bedside assistance. On further review of the ECG, a shark fin (SF) OMI pattern was identified, indicative of an extensive anterolateral OMI. A bedside echocardiogram revealed a severe left ventricular systolic dysfunction with marked anterolateral and apical akinesia. The patient underwent a successful percutaneous coronary intervention (PCI) to an ostial left anterior descending (LAD) culprit occlusion with hemodynamic support but ultimately died due to multiorgan failure and refractory ventricular arrhythmias. This case illustrates an infrequent OMI presentation (<1.5%) formed by the fusion of the QRS, ST-segment elevation, and T-wave resulting in a wide triangular waveform, giving the appearance of an SF that can also potentially lead to ECG misinterpretation as VT. It also highlights the importance of recognizing STEMI-equivalent ECG patterns to avoid delays in reperfusion therapy. The SF OMI pattern has also been associated with a large amount of ischemic myocardium (such as with left main or proximal LAD occlusion) with a higher mortality risk from cardiogenic shock and/or VF. This high-risk OMI pattern should lead to a more definite reperfusion treatment, such as primary PCI and the possible need for backup hemodynamic support.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
05:36Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Dysrhythmias III: Characteristics of Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
