Use of Ripple mapping to enhance localization and ablation of outflow tract premature ventricular contractions
Kelly Arps1,2, Adam S Barnett1,3, Jason I Koontz1,4
1Division of Cardiovascular Disease, Section of Cardiac Electrophysiology, Duke University Medical Center, Durham, North Carolina, USA.
Introduction:
Accurate localization of septal outflow tract premature ventricular contractions (PVCs) is often difficult due to frequent mid-myocardial or protected origin. Compared with traditional activation mapping, CARTO Ripple mapping provides visualization of all captured electrogram data without assignment of a specific local activation time and thus may enhance PVC localization.
Methods:
Electroanatomic maps for consecutive catheter ablation procedures for septal outflow tract PVCs (July 2018-December 2020) were analyzed. For each PVC, we identified the earliest local activation point (EA), defined by the point of maximal -dV/dt in a simultaneously recorded unipolar electrogram, and the earliest Ripple signal (ERS), defined as the earliest point at which three grouped simultaneous Ripple bars appeared in late diastole. Immediate success was defined as full suppression of the clinical PVC.
Results:
Fifty-seven unique PVCs in 55 procedures were included. When ERS and EA were in the same chamber (RV, LV, or CS), the odds ratio for the successful procedure was 13.1 (95% confidence interval [CI] 2.2-79.9, p = .005). Discordance between sites was associated with a higher likelihood of needing multi-site ablation (odds ratio [OR] 7.9 [1.4-4.6; p = .020]). Median EA-ERS distance in successful versus unsuccessful cases was 4.6 mm (interquartile range 2.9-8.5) versus 12.5 mm (7.8-18.5); (p = .020).
Conclusion:
Greater EA-ERS concordance was associated with higher odds of single-site PVC suppression and successful septal outflow tract PVC ablation. Visualization of complex signals via automated Ripple mapping may offer rapid localization information complementary to local activation mapping for PVCs of mid-myocardial origin.