Related Experiment Video
Updated: Jul 27, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Achievable Dosimetric Constraints in Stereotactic Reirradiation for Recurrent Prostate Cancer
Manon Baty1, David Pasquier2, Khemara Gnep1
1Department of Radiotherapy, Center Eugène Marquis, Rennes, France.
Purpose:
Stereotactic body radiation therapy has been proposed as a salvage treatment for recurrent prostate cancer after irradiation. One crucial issue is choosing appropriate dose-volume constraints (DVCs) during planning. The objectives of this study were to (1) quantify the proportion of patients respecting the DVCs according to the Urogenital Tumor Study Group GETUG-31 trial, testing 36 Gy in six fractions, (2) explain geometrically why the DVCs could not be respected, and (3) propose the most suitable DVCs.
Methods And Materials:
This retrospective dosimetric analysis included 141 patients treated for recurrent prostate cancer with Cyberknife (Accuray), according to GETUG-31 DVCs: V95% ≥ 95% for the planning target volume (PTV), V12Gy < 20% and V27Gy < 2 cc for the rectum, and V12Gy < 15% and V27Gy < 5 cc for the bladder. The percentage of patients not respecting the DVCs was quantified. Correlations between the DVCs and anatomic structures were examined. New DVCs were proposed.
Results:
Only 19% of patients respected all DVCs, with a mean PTV of 18.5 cc (range, 3-48 cc), although the mean PTV was 40.5 cc (range, 3-174 cc) in the whole series. A total of 98% of the patients with a clinical target volume (CTV)/prostate ratio >0.5 could not respect the DVCs in the organs at risk. The target coverage and organ-at-risk sparing decreased significantly with increase in the values of PTV, CTV, CTV/prostate ratio, the overlapping volume between the PTV and bladder wall and between the PTV and rectal wall. Threshold values of PTV, >20 cc and 40 cc, allowed for the PTV and bladder DVCs, respectively. To improve DVC respect in case of large target volume, we proposed the following new DVCs: V12Gy < 25% and 25% and V27Gy < 2 cc and 5 cc for the rectum and bladder, respectively.
Conclusions:
GETUG-31 DVCs are achievable only for small target volumes (CTV more than half of the prostate). For a larger target volume, new DVCs have been proposed.