Effect of Stabilized Martensite on the Long-Term Performance of Superelastic NiTi Endodontic Files
Patricia Sánchez1, Benedetta Vidi2,3, Jesús Mena-Alvarez3
1Bioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallés, Spain.
Abstract:
One of the most used rotary files in endodontics is NiTi files due to their superelastic properties. This property means that this instrument has extraordinary flexion that can adapt to large angles inside the tooth canals. However, these files lose their superelasticity and fracture during use. The aim of this work is to determine the cause of fracture of the endodontic rotary files. For this purpose, 30 NiTi F6 SkyTaper® files (Komet, Germany) were used. Their chemical composition was determined by X-ray microanalysis, and their microstructure was determined by optical microscopy. Successive drillings were carried out with artificial tooth molds at 30, 45, and 70°. These tests were carried out at a temperature of 37 °C with a constant load controlled by a high sensitivity dynamometer of 5.5 N, and every five cycles were lubricated with an aqueous solution of sodium hypochlorite. The cycles to fracture were determined, and the surfaces were observed by scanning electron microscopy. Transformation (austenite to martensite) and retransformation (martensite to austenite) temperatures and enthalpies were determined by Differential Scanning Calorimeter at different endodontic cycles. The results showed an original austenitic phase with a Ms temperature of 15 °C and Af of 7 °C. Both temperatures increase with endodontic cycling, indicating that martensite forms at higher temperatures, and the temperature must be increased with cycling to retransform it to austenite. This fact indicates the stabilization of martensite with cycling, which is confirmed by the decrease in both transformation and retransformation enthalpies. The martensite is stabilized in the structure due to defects and does not retransform. This stabilized martensite has no superelasticity and, therefore, fractures prematurely. It has been possible to observe the stabilized martensite by studying the fractography, observing that the mechanism is by fatigue. The results showed that the files fracture earlier the greater the angle applied (for the tests at 70° at 280 s, at 45° at 385 s, and at 30° at 1200 s). As the angle increases, there is an increase in mechanical stress, and, therefore, the martensite stabilizes at lower cycles. To destabilize the martensite, a heat treatment can be carried out at 500 °C for 20 min, and the files recovers all its superelasticity.
More Related Videos
06:53Author Spotlight: Rapid Prototyping and Testing of Self-Expanding Nitinol Frames for Transcatheter Implantable Devices
Published on: March 7, 2025
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Plastic Behavior
Residual Stresses
Stress-Strain Diagram - Ductile Materials
Residual Stresses in Bending
Hooke's Law
Residual Stresses in Circular Shafts