Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Increased Dead Space Ventilation as a Contributing Factor to Persistent Exercise Limitation in Patients with a Left
Simon Wernhart1, Bastian Balcer1, Tienush Rassaf1
1Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147 Essen, Germany.
Abstract:
(1) Background: The exercise capacity of patients with a left ventricular assist device (LVAD) remains limited despite mechanical support. Higher dead space ventilation (VD/VT) may be a surrogate for right ventricular to pulmonary artery uncoupling (RV-PA) during cardiopulmonary exercise testing (CPET) to explain persistent exercise limitations. (2) Methods: We investigated 197 patients with heart failure and reduced ejection fraction with (n = 89) and without (HFrEF, n = 108) LVAD. As a primary outcome NTproBNP, CPET, and echocardiographic variables were analyzed for their potential to discriminate between HFrEF and LVAD. As a secondary outcome CPET variables were evaluated for a composite of hospitalization due to worsening heart failure and overall mortality over 22 months. (3) Results: NTproBNP (OR 0.6315, 0.5037-0.7647) and RV function (OR 0.45, 0.34-0.56) discriminated between LVAD and HFrEF. The rise of endtidal CO2 (OR 4.25, 1.31-15.81) and VD/VT (OR 1.23, 1.10-1.40) were higher in LVAD patients. Group (OR 2.01, 1.07-3.85), VE/VCO2 (OR 1.04, 1.00-1.08), and ventilatory power (OR 0.74, 0.55-0.98) were best associated with rehospitalization and mortality. (4) Conclusions: LVAD patients displayed higher VD/VT compared to HFrEF. Higher VD/VT as a surrogate for RV-PA uncoupling could be another marker of persistent exercise limitations in LVAD patients.
More Related Videos
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Mitral Stenosis I: Introduction
Heart Failure VI: Adjunct Therapies
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiomyopathy V: Interprofessional Care
Heart Failure III: Clinical Manifestations