Related Experiment Video
Updated: Jul 27, 2025

Robotized Testing of Camera Positions to Determine Ideal Configuration for Stereo 3D Visualization of Open-Heart Surgery
Published on: August 12, 2021
Noniterative Generalized Camera Model for Near-Central Camera System
Taehyeon Choi1, Seongwook Yoon1, Jaehyun Kim1
1School of Electrical Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
Abstract:
This paper proposes a near-central camera model and its solution approach. 'Near-central' refers to cases in which the rays do not converge to a point and do not have severely arbitrary directions (non-central cases). Conventional calibration methods are difficult to apply in such cases. Although the generalized camera model can be applied, dense observation points are required for accurate calibration. Moreover, this approach is computationally expensive in the iterative projection framework. We developed a noniterative ray correction method based on sparse observation points to address this problem. First, we established a smoothed three-dimensional (3D) residual framework using a backbone to avoid using the iterative framework. Second, we interpolated the residual by applying local inverse distance weighting on the nearest neighbor of a given point. Specifically, we prevented excessive computation and the deterioration in accuracy that may occur in inverse projection through the 3D smoothed residual vectors. Moreover, the 3D vectors can represent the ray directions more accurately than the 2D entities. Synthetic experiments show that the proposed method can achieve prompt and accurate calibration. The depth error is reduced by approximately 63% in the bumpy shield dataset, and the proposed approach is noted to be two digits faster than the iterative methods.
More Related Videos
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Curvilinear Motion: Normal and Tangential Components
The positive direction of the t-axis aligns with the increasing position of the car along the curved path, denoted by the unit vector ut. Simultaneously, the n-axis, perpendicular to the t-axis, dissects the curved path into differential arc segments, each forming the arc of a circle with a radius of...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...