Comparison of two ultrasound-guided techniques for radial arterial cannulation in adults - Observational
M K Safiya Sherrin1, Paul O Raphael1, Lini Chacko1
1Department of Anaesthesiology, Amala Institute of Medical Sciences, Thrissur, Kerala, India.
Background And Aims:
Short axis, out of plane (SAOOP) and long axis, in-plane (LAIP) are two approaches employed under ultrasound-guided radial arterial cannulation. Dynamic needle tip positioning (DNTP) is a recently introduced approach which integrates the features of both.
Methods:
A total of 114 adult patients from American Society of Anaesthesiologists (ASA) I-IV were studied in this hospital-based cross-sectional study after getting Institutional Ethical approval, CTRI registration and prior written informed consent. The primary objective was to compare the success rates among LAIP and DNTP techniques. The radial arterial diameter and its depth were correlated to the success rates in both. Statistical analysis was done using SPSS version 23.0.
Results:
Success rates were similar in both (P value-0.094). Ultrasonographic location time (in seconds) was shorter in DNTP (4.351 ± 0.9727) compared to LAIP (7.140 ± 1.0763) (P value-0.0001). The mean overall diameter and depth of radial artery (in mm) were found to be 2.36 ± 0.02 and 2.51 ± 0.12, respectively. Pearson's correlation coefficient between cannulation time and diameter was found to be -0.602 (P value-0.0001) and with depth of the radial artery was 0.034 (P value 0.723).
Conclusion:
The success rates were similar in both techniques. Ultrasonographic location time of the radial artery was more in LAIP although cannulation time was similar in both. Cannulation time decreased with an increase in the diameter of radial artery but was unaffected by the depth of the radial artery.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: