Related Experiment Video
Updated: Jul 27, 2025

Design and Characterization Methodology for Efficient Wide Range Tunable MEMS Filters
Published on: February 4, 2018
A new efficiency calibration methodology for different atmospheric filter geometries by using coaxial Ge detectors
1Radiation Physics and Environment Group (FRYMA), Department of Integrated Sciences, Center for Natural Resources, Health and Environment (RENSMA), University of Huelva, 21071 Huelva, Spain.
Abstract:
The study of the different pollutants present in atmospheric aerosols such as trace elements and radionuclides is essential to assess the air quality. To analyze the particulate matter (PM), atmospheric filters with different dimensions and geometries (rectangular, circular, slotted, and square filters) are usually employed. Regarding the pollutants existing in atmospheric aerosols, radionuclides are usually analyzed due to their multiple applications such as either in the environmental radiological control or as tracers of atmospheric processes. Therefore, this study aims to develop a new and general methodology to calibrate in efficiency coaxial Ge detectors to properly determine radionuclides present in the PM by gamma-ray spectrometry for several filter types. For this, granular certified reference materials (CRM) containing only natural radionuclides (238U-series, 232Th-series, and 40 K) were selected. Several granular solid CRMs were chosen allowing us to reproduce the same PM deposition geometry and to assure the homogeneity of the added CRMs. These are the main advantages in relation to the typical methods that use liquid CRMs. Furthermore, for filters whose surfaces are relatively large, they were cut in several pieces and placed one on top of the other, achieving the same geometry than the PM deposited onto the filter. Then, the experimental full-energy peak efficiencies (FEPEs) were obtained for each energy of interest (E) and they were fitted versus E, finding a general FEPE function for each filter type. Finally, this methodology was validated for both natural and artificial radionuclides (from 46 to 1332 keV) by using different filter types employed in proficiency test exercises, obtaining |zscore|< 2 for all cases.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s11869-023-01336-x.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Calibration Curves: Correlation Coefficient

