Related Experiment Video
Updated: Jul 26, 2025

Echocardiography Recording in Awake Miniature Pigs
Published on: May 26, 2023
Echocardiography Recording in Awake Miniature Pigs
Talli Hogen1, Jing Li2, Pia Balmaceda1
1Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah.
Abstract:
Echocardiography uses ultrasonic waves to non-invasively assess cardiac structure and function and is the standard of care for cardiac assessment and monitoring. The miniature pig, or minipig, is increasingly being used as a model of cardiac disease in medical research. Pigs are notoriously difficult to restrain and handle safely, and, therefore, research echocardiography in this species is almost always performed under anesthesia or heavy sedation. Anesthetics and sedatives universally affect cardiovascular function and may cause the depression of cardiac output and blood pressure, increases or decreases in heart rate and systemic vascular resistance, changes in the electrical rhythm, and altered coronary blood flow. Therefore, sedated or anesthetized echocardiography may not accurately depict the progression of cardiac disease in large animal models, thereby limiting the translational value of these important studies. This paper describes a novel device that allows for standing awake echocardiography in minipigs. In addition, training techniques used to teach pigs to tolerate this painless and non-invasive procedure without the need for hemodynamic-altering anesthetics are described. Standing awake echocardiography represents a safe and feasible way to perform the most common cardiac monitoring test in minipigs for cardiovascular research.