Estimation of confidence intervals for quantitation of coeluted peaks in liquid chromatography-Photodiode array
Yusuke Tamai1, Akira Noda1, Eiichi Yamamoto2
1Shimadzu Corporation, Technology Research Laboratory, 3-9-4 Hikaridai, Seika-cho, Soraku-gun, Kyoto 619-0237, Japan.
Abstract:
There is a dramatic increase in drug candidates that exhibit complex structures and do not comply with Lipinski's rule of five. One of the most critical and complex technical challenges in the quality control of such drug candidates is the control of analogous substances contained in active pharmaceutical ingredients and related formulations. Although the development of ultrahigh-performance liquid chromatography and high-performance columns has improved efficiency per unit time, the difficulty of peak separation to quantify impurities with similar structures and physicochemical properties continues to rise, and so does the probability of failure to achieve the necessary separation. Coeluting peaks observed in the case of high-performance liquid chromatography (HPLC) with photodiode array detection can be separated using the multivariate curve resolution-alternating least-square (MCR-ALS) method exploiting differences in analyte UV spectra. However, relatively large quantitation errors have been observed for coeluting analogous substances, and the reliability of the corresponding quantitative data requires improvement. Herein, Bayesian inference is applied to separation by the MCR-ALS method to develop an algorithm assigning a confidence interval to the quantitative data of each analogous substance. The usefulness and limitations of this approach are tested using two analogs of telmisartan as models. For this test, a simulated two-component HPLC-UV dataset with an intensity ratio (relative to the main peak) of 0.1-1.0 and a resolution of 0.5-1.0 is used. The developed algorithm allows the prediction confidence interval, including the true value, to be assigned to the peak area in almost all cases, even when the intensity ratio, resolution, and signal-to-noise ratio are changed. Finally, the developed algorithm is also evaluated on a real HPLC-UV dataset to confirm that reasonable prediction confidence intervals including true values are assigned to peak areas. In addition to allowing the separation and quantitation of substances such as impurities challenging to separate by HPLC in a scientifically valid manner, which is impossible for conventional HPLC-UV detection, our method can assign confidence intervals to quantitative data. Therefore, the adopted approach is expected to resolve the issues associated with assessing impurities in the quality control of pharmaceuticals.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...