Related Experiment Video
Updated: Jul 26, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Automatic and human level Graf's type identification for detecting developmental dysplasia of the hip
Yueh-Peng Chen1, Tzuo-Yau Fan2, Cheng-Cj Chu3
1Center for Artificial Intelligence in Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Master of Science Degree Program in Innovation for Smart Medicine, Chang Gung University, Taoyuan, Taiwan.
Background:
Developmental dysplasia of the hip (DDH) is a common congenital disorder that may lead to hip dislocation and requires surgical intervention if left untreated. Ultrasonography is the preferred method for DDH screening; however, the lack of experienced operators impedes its application in universal neonatal screening.
Methods:
We developed a deep neural network tool to automatically register the five keypoints that mark important anatomical structures of the hip and provide a reference for measuring alpha and beta angles following Graf's guidelines, which is an ultrasound classification system for DDH in infants. Two-dimensional (2D) ultrasonography images were obtained from 986 neonates aged 0-6 months. A total of 2406 images from 921 patients were labeled with ground truth keypoints by senior orthopedists.
Results:
Our model demonstrated precise keypoint localization. The mean absolute error was approximately 1 mm, and the derived alpha angle measurement had a correlation coefficient of R = 0.89 between the model and ground truth. The model achieved an area under the receiver operating characteristic curve of 0.937 and 0.974 for classifying alpha <60° (abnormal hip) and <50° (dysplastic hip), respectively. On average, the experts agreed with 96% of the inferenced images, and the model could generalize its prediction on newly collected images with a correlation coefficient higher than 0.85.
Conclusions:
Precise localization and highly correlated performance metrics suggest that the model can be an efficient tool for assisting DDH diagnosis in clinical settings.