Related Experiment Video
Updated: Jul 26, 2025

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Voluntary Deep Inspiration Breath-Hold (VDIBH) Whole-Breast Irradiation Assisted by Optical Surface Monitoring System
Jiang-Hu Zhang1, Tan-Tan Li1, Shi-Rui Qin1
1National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Abstract:
Objectives: To investigate the dosimetric advantages of the voluntary deep inspiration breath-hold technique assisted by optical surface monitoring system for whole breast irradiation in left breast cancer after breast-conserving surgery and verify the reproducibility and acceptability of this technique. Methods: Twenty patients with left breast cancer receiving whole breast irradiation after breast-conserving surgery were enrolled in this prospective phase II study. Computed tomography simulation was performed during both free breathing and voluntary deep inspiration breath-hold for all patients. Whole breast irradiation plans were designed, and the volumes and doses of the heart, left anterior descending coronary artery, and lung were compared between free breathing and voluntary deep inspiration breath-hold. Cone beam computed tomography was performed for the first 3 treatments, then weekly during voluntary deep inspiration breath-hold treatment to evaluate the accuracy of the optical surface monitoring system technique. The acceptance of this technique was evaluated with in-house questionnaires completed by patients and radiotherapists. Results: The median age was 45 (27-63) years. All patients received hypofractionated whole breast irradiation using intensity-modulated radiation therapy up to a total dose of 43.5 Gy/2.9 Gy/15f. Seventeen of the 20 patients received concomitant tumor bed boost to a total dose of 49.5 Gy/3.3 Gy/15f. Voluntary deep inspiration breath-hold showed a significant decrease in the heart mean dose (262 ± 163 cGy vs 515 ± 216 cGy, P < .001) and left anterior descending coronary artery (1191 ± 827 cGy vs 1794 ± 833 cGy, P < .001). The median delivery time of radiotherapy was 4 (1.5-11) min. The median deep breathing cycles were 4 (2-9) times. The average score for acceptance of voluntary deep inspiration breath-hold by patients and radiotherapists was 8.7 ± 0.9 (out of 12) and 10.6 ± 3.2 (out of 15), respectively, indicating good acceptance by both. Conclusions: The voluntary deep inspiration breath-hold technique for whole breast irradiation after breast-conserving surgery in patients with left breast cancer significantly reduces the cardiopulmonary dose. Optical surface monitoring system-assisted voluntary deep inspiration breath-hold is reproducible and feasible and showed good acceptance by both patients and radiotherapists.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...