Related Experiment Video
Updated: Jul 26, 2025

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Screening for degenerative cervical myelopathy with the 10-second grip-and-release test using a smartphone and
Takuya Ibara1, Ryota Matsui2, Takafumi Koyama3
1Department of Functional Joint Anatomy, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
Objective:
Early detection and intervention are essential for the mitigation of degenerative cervical myelopathy (DCM). However, although several screening methods exist, they are difficult to understand for community-dwelling people, and the equipment required to set up the test environment is expensive. This study investigated the viability of a DCM-screening method based on the 10-second grip-and-release test using a machine learning algorithm and a smartphone equipped with a camera to facilitate a simple screening system.
Methods:
Twenty-two participants comprising a group of DCM patients and 17 comprising a control group participated in this study. A spine surgeon diagnosed the presence of DCM. Patients performing the 10-second grip-and-release test were filmed, and the videos were analyzed. The probability of the presence of DCM was estimated using a support vector machine algorithm, and sensitivity, specificity, and area under the curve (AUC) were calculated. Two assessments of the correlation between estimated scores were conducted. The first used a random forest regression model and the Japanese Orthopaedic Association scores for cervical myelopathy (C-JOA). The second assessment used a different model, random forest regression, and the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire.
Results:
The final classification model had a sensitivity of 90.9%, specificity of 88.2%, and AUC of 0.93. The correlations between each estimated score and the C-JOA and DASH scores were 0.79 and 0.67, respectively.
Conclusions:
The proposed model could be a helpful screening tool for DCM as it showed excellent performance and high usability for community-dwelling people and non-spine surgeons.