Related Experiment Video
Updated: Sep 30, 2026

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
An evaluation of the Avionics Pressurometer III 1978 at home and in hospital
Abstract:
The Avionics Pressurometer III is the only noninvasive indirect ambulatory blood pressure system which provides 24-h blood pressure measurements, but it has been subjected to limited evaluation. We report a critical evaluation comparing it to simultaneous intra-arterial blood pressures both at home and at hospital as well as during standardized exercise. Comparisons with simultaneous indirect methods were also made. Twenty-two hypertensives undergoing intra-arterial ambulatory blood pressure monitoring wore the two recorders for one day. The mean difference (standard deviation SD) for intra-arterial blood pressure--Avionics blood pressure was 2 (SD 8.6)/-14 (SD 10.3) mmHg at home and -3 (SD 15.4)/-11 (SD 12.3) mmHg at hospital. At the end of exercise the figures for the same comparison were -7 (SD 16)/0 (SD 15.6) mmHg. In general the agreement between intra-arterial and Avionics pressurometer recordings was closer for systolic than for diastolic blood pressures but there was wide variation for individuals as shown by the standard deviations about the mean difference. We did not use the recorder at night as patients complained that the noise kept them awake and so night-time blood pressures were not attainable. We do not think the recorder performed satisfactorily during physical exertion, and in view of its expense, this recorder is of limited potential value in supplying accurate information.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

