Related Experiment Video
Updated: Jul 26, 2025

An In Vitro Skin Irritation Test SIT using the EpiDerm Reconstructed Human Epidermal RHE Model
Published on: July 13, 2009
Fit evaluation of NIOSH approved N95 filtering facepiece respirators with various skin protectants: A pilot study
Michael S Bergman1, Sergey A Grinshpun2, Michael V Yermakov2
1National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Washington, District of Columbia, USA.
Abstract:
Widespread disease outbreaks can result in prolonged wear times of National Institute for Occupational Safety and Health Approved N95 filtering facepiece respirators by healthcare personnel. Prolonged wear times of these devices can cause the development of various adverse facial skin conditions. Healthcare personnel have been reported to apply "skin protectants" to the face to reduce the pressure and friction of respirators. Because tight-fitting respirators rely on a good face seal to protect the wearer, it is important to understand if the fit is affected when skin protectants are used. This laboratory pilot study included 10 volunteers who performed quantitative fit tests to evaluate respirator fit while wearing skin protectants. Three N95 filtering facepiece respirator models and three skin protectants were evaluated. Three replicate fit tests were performed for each combination of subject, skin protectant (including a control condition of no protectant), and respirator model. Fit Factor (FF) was affected differently by the combination of the protectant type and respirator model. The main effects of the protectant type and respirator model were both significant (p < 0.001); additionally, their interaction was significant (p = 0.02), indicating FF is affected by the combined effects of the protectant type and respirator model. Compared to the control condition, using a bandage-type or surgical tape skin protectant decreased the odds of passing the fit test. Using a barrier cream skin protectant also decreased the odds of passing the fit test across all models compared to the control condition; however, the probability of passing a fit test was not statistically significantly different from the control condition (p = 0.174). These results imply that all three skin protectants reduced mean fit factors for all N95 filtering facepiece respirator models tested. The bandage-type and surgical tape skin protectants both reduced fit factors and passing rates to a greater degree than the barrier cream. Respirator users should follow respirator manufacturers' guidance on the use of skin protectants. If a skin protectant is to be worn with a tight-fitting respirator, the fit of the respirator should be evaluated with the skin protectant applied before use in the workplace.
Related Concept Videos
Personal Protective Equipment
PPE Use in Healthcare Settings I: Donning
PPE Use in Healthcare Settings II: Doffing
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...

