Cardiac output estimated from an uncalibrated radial blood pressure waveform: validation in an in-silico-generated

Vasiliki Bikia1, Georgios Rovas1, Nikolaos Stergiopulos1

  • 1Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology, Lausanne, Switzerland.

Insights

This study developed artificial neural networks to estimate cardiac output from blood pressure waveforms. The uncalibrated waveform shows promise for non-invasive hemodynamic monitoring, especially with wearable technology.

Area of Science:

  • Biomedical Engineering
  • Cardiovascular Physiology
  • Artificial Intelligence in Medicine

Background:

  • Cardiac output monitoring is crucial for critically ill patients.
  • Current methods are invasive, costly, and carry risks.
  • A non-invasive, accurate method for cardiac output determination is needed, with wearable technology offering potential.

Purpose of the Study:

  • To develop an artificial neural network (ANN) model for estimating cardiac output using radial blood pressure waveforms.
  • To investigate if uncalibrated radial blood pressure waveforms contain sufficient information for accurate cardiac output estimation.
  • To compare the performance of ANN models using calibrated versus uncalibrated waveforms.

Main Methods:

  • Development of an ANN-enabled modeling approach using in silico data from 3,818 virtual subjects.
  • Training and testing of two ANN models: ANNcalradBP (calibrated waveform) and ANNuncalradBP (uncalibrated waveform).
  • Analysis of model sensitivity to cardiovascular parameters like heart rate and blood pressure.

Main Results:

  • Both ANN models accurately estimated cardiac output across diverse cardiovascular profiles.
  • ANNcalradBP demonstrated higher accuracy than ANNuncalradBP.
  • Pearson's correlation coefficients were 0.98 for ANNcalradBP and 0.95 for ANNuncalradBP.

Conclusions:

  • Uncalibrated radial blood pressure waveforms provide sufficient information for accurate cardiac output estimation in silico.
  • The findings support the potential clinical utility of non-invasive cardiac output monitoring using wearable sensors.
  • Further validation with in vivo human data is required to confirm clinical applicability.

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.4K
Cardiac Output and Stroke Volume01:11

Cardiac Output and Stroke Volume

Cardiac output (CO) is an integral aspect of human physiology, reflecting the heart's efficiency and responsiveness to the body's needs. It represents the volume of blood that the left or right ventricle ejects into the aorta or pulmonary trunk each minute. The CO is calculated by multiplying the heart rate (HR)—the number of heartbeats per minute—by the stroke volume (SV)—the amount of blood pumped out with each heartbeat.
In an average resting adult male, the typical cardiac...
3.1K
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
601
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
1.1K
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
888
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
802