Cardiac output estimated from an uncalibrated radial blood pressure waveform: validation in an in-silico-generated
Vasiliki Bikia1, Georgios Rovas1, Nikolaos Stergiopulos1
1Laboratory of Hemodynamics and Cardiovascular Technology, Institute of Bioengineering, Swiss Federal Institute of Technology, Lausanne, Switzerland.
Insights
This study developed artificial neural networks to estimate cardiac output from blood pressure waveforms. The uncalibrated waveform shows promise for non-invasive hemodynamic monitoring, especially with wearable technology.
Area of Science:
- Biomedical Engineering
- Cardiovascular Physiology
- Artificial Intelligence in Medicine
Background:
- Cardiac output monitoring is crucial for critically ill patients.
- Current methods are invasive, costly, and carry risks.
- A non-invasive, accurate method for cardiac output determination is needed, with wearable technology offering potential.
Purpose of the Study:
- To develop an artificial neural network (ANN) model for estimating cardiac output using radial blood pressure waveforms.
- To investigate if uncalibrated radial blood pressure waveforms contain sufficient information for accurate cardiac output estimation.
- To compare the performance of ANN models using calibrated versus uncalibrated waveforms.
Main Methods:
- Development of an ANN-enabled modeling approach using in silico data from 3,818 virtual subjects.
- Training and testing of two ANN models: ANNcalradBP (calibrated waveform) and ANNuncalradBP (uncalibrated waveform).
- Analysis of model sensitivity to cardiovascular parameters like heart rate and blood pressure.
Main Results:
- Both ANN models accurately estimated cardiac output across diverse cardiovascular profiles.
- ANNcalradBP demonstrated higher accuracy than ANNuncalradBP.
- Pearson's correlation coefficients were 0.98 for ANNcalradBP and 0.95 for ANNuncalradBP.
Conclusions:
- Uncalibrated radial blood pressure waveforms provide sufficient information for accurate cardiac output estimation in silico.
- The findings support the potential clinical utility of non-invasive cardiac output monitoring using wearable sensors.
- Further validation with in vivo human data is required to confirm clinical applicability.
Abstract:
Background: Cardiac output is essential for patient management in critically ill patients. The state-of-the-art for cardiac output monitoring bears limitations that pertain to the invasive nature of the method, high costs, and associated complications. Hence, the determination of cardiac output in a non-invasive, accurate, and reliable way remains an unmet need. The advent of wearable technologies has directed research towards the exploitation of wearable-sensed data to improve hemodynamical monitoring. Methods: We developed an artificial neural networks (ANN)-enabled modelling approach to estimate cardiac output from radial blood pressure waveform. In silico data including a variety of arterial pulse waves and cardiovascular parameters from 3,818 virtual subjects were used for the analysis. Of particular interest was to investigate whether the uncalibrated, namely, normalized between 0 and 1, radial blood pressure waveform contains sufficient information to derive cardiac output accurately in an in silico population. Specifically, a training/testing pipeline was adopted for the development of two artificial neural networks models using as input: the calibrated radial blood pressure waveform (ANNcalradBP), or the uncalibrated radial blood pressure waveform (ANNuncalradBP). Results: Artificial neural networks models provided precise cardiac output estimations across the extensive range of cardiovascular profiles, with accuracy being higher for the ANNcalradBP. Pearson's correlation coefficient and limits of agreement were found to be equal to [0.98 and (-0.44, 0.53) L/min] and [0.95 and (-0.84, 0.73) L/min] for ANNcalradBP and ANNuncalradBP, respectively. The method's sensitivity to major cardiovascular parameters, such as heart rate, aortic blood pressure, and total arterial compliance was evaluated. Discussion: The study findings indicate that the uncalibrated radial blood pressure waveform provides sample information for accurately deriving cardiac output in an in silico population of virtual subjects. Validation of our results using in vivo human data will verify the clinical utility of the proposed model, while it will enable research applications for the integration of the model in wearable sensing systems, such as smartwatches or other consumer devices.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Pre-Procedural Guidelines for Assessing Blood Pressure
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation