Scipion Flexibility Hub: an integrative framework for advanced analysis of conformational heterogeneity in cryoEM

D Herreros1, J M Krieger1, Y Fonseca1

  • 1Centro Nacional de Biotecnologia - CSIC, Calle Darwin 3, 28049 Madrid, Spain.

Related Concept Videos

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
1.1K
Adaptability of Cytoskeletal Filaments01:12

Adaptability of Cytoskeletal Filaments

The cytoskeleton is a complex dynamic structure performing varied functions based on cellular requirements. The adaptability of the individual filaments in the cytoskeleton determines their ability to perform various functions within the cell. It can undergo rapid reorganization during processes like cell division or remain stable for several hours as in the interphase. The adaptability of these filaments depends on stringent regulatory mechanisms. The microfilament and microtubules of the...
3.8K
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
886
Cryo-electron Microscopy01:28

Cryo-electron Microscopy

Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.4K