Ventilation strategies based on an aerodynamic analysis during a large-scale SARS-CoV-2 outbreak in an acute-care
Se Yoon Park1, Jungyeon Yu2, Sanghwan Bae2
1Department of Hospital Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea; Centers for Digital Health, Yongin Severance Hospital, Yonsei University Health System, Yongin, Republic of Korea; Department of Internal Medicine, Hanyang University College of Medicine, Seoul, Republic of Korea.
Background:
This study aimed to investigate ventilation strategies to prevent nosocomial transmission of coronavirus disease 2019 (COVID-19).
Methods:
We conducted a retrospective epidemiological investigation of a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak in a teaching hospital (February-March 2021). The largest outbreak ward was studied, and measurements were taken to determine the pressure difference and air change per hour (ACH) of the rooms. Airflow dynamics were assessed using an oil droplet generator, indoor air quality sensor, and particle image velocimetry in the index patient's room, corridor, and opposite rooms, by varying the opening and closing of windows and doors.
Results:
During the outbreak, 283 COVID-19 cases were identified. The SARS-CoV-2 spread occurred sequentially from the index room to the nearest room, especially the opposite. The aerodynamic study demonstrated that droplet-like particles in the index room diffused through the corridor and the opposite room through the opening door. The mean ACH of the rooms was 1.44; the air supply volume was 15.9% larger than the exhaust volume, forming a positive pressure. Closing the door prevented diffusion between adjacent rooms facing each other, and natural ventilation reduced the concentration of particles within the ward and minimised their spread to adjacent rooms.
Conclusions:
Spread of droplet-like particles between rooms could be attributed to the pressure difference between the rooms and corridor. To prevent spread of SARS-CoV-2 between rooms, increasing the ACH in the room by maximising ventilation and minimising the positive pressure through supply/exhaust control and closing the room door are essential.
More Related Videos
07:13Swabbing the Urban Environment - A Pipeline for Sampling and Detection of SARS-CoV-2 From Environmental Reservoirs
Published on: April 9, 2021
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...